18" HIGH WALL HOOD CANOPY – 27" DEEP

Models

Number

of Lights

Number

of Filters

Interior-Power

Exterior-Power

Recommended Ventilator Kits

Interior

Exterior

Recommended Duct Size

Interior

Exterior

Maximum Amps

An interior- or exterior-power ventilator kit must be purchased for installation with all hoods.

Outdoor hoods

VWH3678T-36"W

VIV1200

VEV1200/VEV1500

2

2

10"

8.7

6.1/6.8

10"/10"

VWH4878T-48"W

VIV1200

VEV1200/VEV1500

3

3

10"

11.5

8.8/9.5

10"

VWH6078T-60"W

VIV1200

VEV1200/VEV1500

4

4

10"

11.5

8.8/9.5

10"

Ventilator kits

VEV1200

Approximate CFM

1

Recommended Duct Size

Maximum Duct Run

2

Maximum Amps

Description

V E N T I L A T O R K I T S

Interior Ventilators

Exterior Ventilators

VIL1200

VIV1200

1,200

1,200

50 ft. (15.2 m)

50 ft. (15.2 m)

50 ft. (15.2 m)

1,200

S E E H O O D S P E C I F I C A T I O N S

S E E H O O D S P E C I F I C A T I O N S

Please note: Maximum amp rating for hoods includes recommended ventilator kit rating; all products must be hard wired with 2-wire ground. All ventilator kits use 120VAC/60Hz

Proper installation is extremely important to ensure maximum performance from any ventilation product.

1. All CFMs stated based on tests with .1 static pressure; without applying static pressure (some brands consciously do not), CFM could be greatly overstated.

2. Duct run length is for general reference only; for longer duct runs, increase duct size and contact a qualified and trained installer.

• Straight runs and gradual turns are best; for example, each 90-degree elbow is equal to 5-10 feet (1.52-3.05 m) of straight run.

• Never use flexible duct; it creates back pressure/air turbulence and greatly reduces performance.

• Proper performance is dependent upon proper ducting; make sure that a qualified and trained installer is used.

• Check with a qualified and trained installer or local codes for makeup air requirements, if any.

45

Access doors

Description

Overall Width
(including notches)

AD2820T

AD1620T

28 1/4" (71.8 cm) minimum
30 1/4" (76.8 cm) maximum

D O U B L E A N D S I N G L E A C C E S S D O O R S

16 1/4" (41.3 cm) minimum
18 1/4" (46.4 cm) maximum

Overall Height
(opening only)

20 1/4" (51.4 cm) minimum
20 1/2" (52.1 cm) maximum

In-line ventilation kits

VEV1500

1,500

75 ft. (22.8 m)