Vector IVECO MOTOS V08 ENT M12 User Manual

Page 16

Advertising
background image

INSTALLATION DIRECTIVE

16

V08 EnT M75 - M11 - M12

MAY 2006

Fuel supply system scheme

Figure 8

Hydraulic connections

Figure 

1. Vent fitting - 2. Compensation duct between two rails - 3. Common rail - 4. Electro-injector - 5. Low pressure limiter valve -
6. Vent fitting - 7. Twin-cylinder high pressure pump - 8. Pressure control solenoid valve - 9. Pressure sensor - 10. Common rail

overpressure valve - 11. Low pressure recirculation duct - 12. Fuel tank - 13. Prefilter - 14. Manual priming pump - 15. Vent fitting -
16. Recirculation valve for low pressure pump - 17. Low pressure mechanical feed pump - 18. By-pass valve for low pressure pump -

19. Lever for switching filters - 20. Fuel filters - 21. Filter exclusion valves.

1. Fitting for fuel outflow to the tank - 2. Fitting for for fuel inflow from prefilter - 3. Prefilter -

4. Fuel inlet pipe from the tank - 5. Fuel return pipe to the tank.

05_014_V

1

6

15

12

14

13

3

4

10

7

16

3

4

2

11

19

20

18

17

5

8
9

21

21

3

1

2

5

4

05_015_V

Advertising
This manual is related to the following products: