Optical (primary lens calibration), Pre l iminar y – Vidikron 140/150 User Manual

Page 70

Advertising
background image

Installation

58

Vision Model 140/150 Owner’s Operating Manual

PRE

L

IMINAR

Y

OptiCal (Primary Lens Calibration): OptiCal provides the ability to store and recall focus,
zoom and position settings for the primary lens.

To enable OptiCal:

1.

Select Installation from the Main Menu.

2.

Select Geometry and Color from the Installation menu.

3.

Select OptiCal from the Geometry and Color menu.

4.

Press ENTER to check the box labeled OptiCal.

5.

Press EXIT to exit the Geometry and Color menu.

6.

Select Calibration and Test Patterns from the Installation Menu.

7.

Select OptiCal from the Calibration and Test Patterns Menu.

OptiCal gives you a choice of three types of lens calibrations:

A Reference calibration establishes a reference point (starting position) for measuring
relative lens movement. All distances are measured from this reference point. A reference
calibration is lost when power is removed from the projector and occurs on every
power-up as long as OptiCal is enabled.

A Motion calibration determines the characteristics of each motor and values are saved in
the projector’s memory. If OptiCal is enabled and a motion calibration has previously been
done, the projector automatically recalls these settings from memory when it’s being
powered up and a motion calibration will not take place.

A Full calibration performs both a Reference calibration and a Motion calibration.

If no calibration has previously been done you may be prompted to do a Full calibration. If a
motion calibration has been done, you will be prompted to complete a reference calibration.
If both calibrations have been done, the OptiCal checkbox is checked and OptiCal enabled.

When OptiCal is enabled, the Vision 140/150 performs a reference calibration when the
projector is turned on. The lens returns to its last saved position (or actual position, if no
motion calibration has been done previously). Further adjustments to the zoom, focus and
position are automatically saved.

When both OptiCal and Automatic Lens Calibration are enabled, the Vision 140/150
performs a Full calibration when the projector is turned on. During calibration, the shutter
closes and the status LED (see Figure 2-3) displays “LC.”

1. Test

Patterns

Grid

2. Keystone

50

3. White

Field

Uniformity

4. Edge

Shading

5. Color

Gamut

Adjust

6. Color

Levels

7.

Black Field Uniformity

8. Default Color Adjustment

ISF Night

9.

OptiCal

Geometry and Color

1. Test

Patterns

Grid

2.

Test Pattern Level

512

3. Freeze

Image

4. Color

Enable

White

5.

Odd Pixel Adjustment

6. Reserved

7. Clipping

Detector

8. Level

Detector

9. Level

Value

512

0. Aspect

Ratio

Overlay

LumaCal Calibrate

LumaCal

OptiCal Full

Automatic

Lens

Calibration

Calibration and Test Patterns

1. OptiCal control is a preference setting and is retained between power

cycles.

2. OptiCal has no effect on the secondary anamorphic lens, only the

primary lens.

If OptiCal is disabled (refer to OptiCal (Primary Lens Calibration)
above), the Automatic Lens Calibration setting has no effect.

Note

Note