5 maintenance and troubleshooting, 1 lamp and filter replacement, Figure 5-1 . removing the lamp door – Vidikron 140/150 User Manual

Page 93: Figure 5-2 . unlocking the lamp, Maintenance and troubleshooting, Lamp and filter replacement, 1. removing the lamp door, 2. unlocking the lamp, Pre l iminar y

Advertising
background image

Vision Model 140/150 Owner’s Operating Manual

81

PRE

L

IMINAR

Y

5.1
Lamp and Filter
Replacement

The Vision 140/150 uses a Cermax® Xenon lamp to deliver its high brightness. The lamp
should be replaced when it reaches the end of its life (typically 1000 hours), or sooner if a
noticeable degradation in brightness occurs. When you replace a lamp, you should replace
the filters as well.

Keep track of the number of hours the lamp has been in use and be aware of any changes to
brightness. These indicators will help you effectively maintain operation of the projector. To
find out how long the currently-installed lamp has been in service, select Lamp Hours from
the VHD Controller Installation menu (available by selecting Service -> Display Device ->
Configure -> Installation
, in sequence).

For lamp or filter replacement, please contact your nearest Vidikron authorized service
center or Vidikron dealer. Do not attempt to replace the lamp yourself!

1.

Turn off the projector and unplug the power cord. Allow the projector to cool down for
approximately 45 minutes prior to removing the lamp assembly for replacement.

2.

Loosen the two rear Lamp Cover screws (see Figure 5-1) and remove the cover.

Figure 5-1. Removing the Lamp Door

3.

Pull (out) and turn the lamp lock lever, which is located to the left of the lamp module, a
quarter turn counterclockwise to the “unlock” position (Figure 5-2).

Figure 5-2. Unlocking the Lamp

5

Maintenance and Troubleshooting

AC IN 220V 50HZ

Lamp cover - 2 screws

AC IN 220V 50HZ

Advertising