5 automated factory self test program – Dometic MCS15 User Manual

Page 12

Advertising
background image

EN

Operating

MCS5, MCS15

12

The fan can be programmed to run only when cooling or heating is required.
Normally the automatic fan speed operation is reversed in the Heating Mode,
however, the fan can be programmed to operate the same as in the Cooling
Mode.

7.5

Automated Factory Self Test Program

The Marine Climate System software provides a self test program to facilitate
factory testing of the entire air conditioning system. Once the self test pro-
gram is activated, the test cycle will continue until the AC power is interrupted
or the Power Button is pressed once which returns the system to the Off
Mode.

➤ Activate the self test program by pressing the Power Button while turning

on the AC power.

➤ Release the Power Button while the display indicates “888” and all LEDs

are lit.

✓ The Marine Climate System is now in the self test program.
✓ “tSt” appears in the display while in the self test program.
Once activated the self test software will continuously execute the following
procedure:

Turn on in the Heat Mode and supply heating for 10 min.

Stop heating and run the fan only for 5 min.

Switch to Cool Mode and continue cooling for 10 min.

Stop cooling and run the fan only for 5 min.

Return to step one and continue until interrupted.

The self test program will continue until the power is interrupted or the test is
halted by pressing the Power Button once.

Advertising