Dometic MCS15 User Manual

Page 34

Advertising
background image

EN

Technical data

MCS5, MCS15

34

13.2

System Control Specifications

13.3

System Inputs

Versions, technical improvements and delivery options reserved.

Set Point Operating Range:

65 °F to 85 °F (18.3 °C to 29.4 °C)

Ambient Temperature Operating Range
Displayed:

5 °F to 150 °F (–15 °C to 65.6 °C)

Sensor Accuracy:

± 2 °F at 77 °F (±1.1 °C at 25 °C)

Low Voltage Limit 230 V Units:

175 V~

Low Voltage Processor Reset:

50 V~

Line Voltage:

230 V~

Frequency:

50 or 60 Hz

Fan Output:

6 A at 230 V~

Valve Output:

0.25 A at 230 V~

Heater Output:

20 A at 230 V~

Pump Output:

1/2 HP at 230 V~

Compressor Output:

2 HP at 230 V~

Minimum Operating Temperature:

0 °F (–17.8 °C)

Maximum Ambient Operating
Temperature:

180 °F (82.2 °C)

Maximum Rh Conditions:

99 % Non Condensing

Power Consumption

< 5 W

Ambient Inside Air Temperature:

1

High Freon Pressure:

1

Low Freon Pressure (Not used in MCS): 1

Alternate Inside Air Temperature Sensor
(Optional):

1

Outside Air Temperature Sensor
(Optional):

1

Advertising