Maintenance

10.1

Reversing Valve

The reversing valve must be energized periodically to keep the internal parts
moving freely.

➤ Switch the air conditioner unit into heat for a few seconds once a month.

10.2

Seawater Strainer

➤ Ensure that your pump receives adequate seawater flow by regularly

cleaning the strainer basket.

➤ Periodically check the overboard discharge for a steady stream of water.
➤ Check seawater intake speed scoop for obstructions.
➤ Make sure hoses are not looped, kinked or crushed.

10.3

Condenser Coil Cleaning

I

NOTE
For the purpose of protecting the environment, dispose of any con-
taminated acid solutions in accordance with federal, state and/or
local regulations.

Coils can become fouled over a period of time due to marine growth or scale
build-up. This both obstructs water flow and prohibits proper heat transfer.

➤ Turn off the system at the circuit breaker on the ship’s panel.
➤ Disconnect the inlet and outlet connections of the condenser coil.
➤ Place a strainer or piece of screen over the inlet of the pump.
➤ Submerse the pump into a container filled with a 5 % solution of muriatic

or hydrochloric acid and fresh water or use a premixed over-the-counter
solution.

!

CAUTION!
Avoid spilling or splashing the solution.
Follow all warnings and recommendations given by the manufac-
turer of any acids or premixed solutions.