6 rebuilding the raid, Exiting the intel, Rapid storage technology utility -31 – Asus RS726Q-E7/RS12 User Manual

Page 149: Rebuilding the raid -31, 5 exiting the intel, Rapid storage technology utility, Rebuilding the raid with other non-raid disk

Advertising
background image

6-31

ASUS RS720Q-E7/RS12, RS724Q-E7/RS12, RS726Q-E7/RS12

Select a destination disk with the same size as the original hard disk.

[

DEGRADED VOLUME DETECTED

]

[↑↓]-Previous/Next [ENTER]-Select [ESC]-Exit

"Degraded" volume and disk available for rebuilding detected. Selecting

a disk initiates a rebuild. Rebuild completes in the operating system.

Select the port of destination disk for rebuilding (ESC to exit):

P o r t D r i v e M o d e l S e r i a l # S i z e

X XXXXXXXXXXX XXXXXXXX XX.XGB

6.3.6

Rebuilding the RAID

This option is only for the RAID 1 set.

Rebuilding the RAID with other non-RAID disk

If any of the SATA hard disk drives included in the RAID 1 array failed, the system

displays the status of the RAID volume as “Degraded” during POST. You can

rebuild the RAID array with other installed non-RAID disks.
To rebuild the RAID with other non-RAID disk:
1. At the prompt, press <Ctrl> + <I> to enter the Intel Rapid Storage Technology

option ROM utility.

2. If there is a non-RAID SATA Hard Disk available, the utility will prompt to

rebuild the RAID. Press <Enter>, and then use up/down arrow keys to select

the destination disk or press <ESC> to exit.

6.3.5

Exiting the Intel

®

Rapid Storage Technology utility

To exit the utility:
1. From the utility main menu, select 4. Exit, and then press <Enter>. The

following warning message appears.

2. Press <Y> to exit or press <N> to return to the utility main menu.

Are you sure you want to exit? (Y/N):

[

CONFIRM EXIT

]

Advertising
This manual is related to the following products: