Anritsu MG3700A User Manual

Page 8

Advertising
background image

8

CDMA2000 1xEV-DO waveform pattern

Standard

CDMA2000 1xEV-DO waveform pattern:

The CDMA2000 1xEV-DO waveform patterns listed on the right

are provided on the MG3700A internal hard disk.

The signals for testing the receiver and transmitter of the

CDMA2000 1xEV-DO access network (base station) and

access terminal (mobile station), which are specified in 3GPP2,

can be output by selecting one of these CDMA2000 1xEV-DO

waveform patterns. Thirteen forward and ten reverse data rate

waveform patterns are available.

When multi-carrier signals, mixed signals of idle and active,

and/or multi-user signals are required, parameter setting and

waveform pattern generation are available using the optional

MX370103A CDMA2000 1xEV-DO IQproducer.

Example of selecting a waveform pattern

Access terminal (AT) receiver test

CDMA2000 1xEV-DO forward

Base band filter: IS-95SPEC +EQ

Data: PN15fix

(excluding FWD-Idle)

FWD_38_4kbps_16slot

FWD_76_8kbps_8slot

FWD_153_6kbps_4slot

FWD_307_2kbps_2slot

FWD_614_4kbps_1slot

FWD_307_2kbps_4slot

FWD_614_4kbps_2slot

FWD_1228_8kbps_1slot

FWD_921_6kbps_2slot

FWD_1843_2kbps_1slot

FWD_1228_8kbps_2slot

FWD_2457_6kbps_1slot

FWD_Idle

Access network (AN) receiver test

CDMA2000 1xEV-DO Reverse

Base band filter: IS-95SPEC

Data: PN9fix

RVS_9_6kbps_RX

RVS_19_2kbps_RX

RVS_38_4kbps_RX

RVS_76_8kbps_RX

RVS_153_6kbps_RX

RVS_9_6kbps_TX

RVS_19_2kbps_TX

RVS_38_4kbps_TX

RVS_76_8kbps_RT

RVS_153_6kbps_RT

This is a PN sequence delimited for each packet. Therefore, the PN

sequence is discontinuous between the end data of a packet and the

start data of the next packet.

MG3700A Vector Signal Generator

AT control, PER calculation

AT

Modulation signal
(Downlink)

Access terminal (AT) receiver test

3GPP2 C.S0033 standard receiver tests (PER: Packet Error Rate) can be performed by selecting a forward signal pattern

required for testing the AT. No protocol is supported for the access network simulator. In addition, all the transmission channels

are traffic, and all the other channels (e.g., Sync) are unsupported; it is necessary to calculate the PER by controlling the AT

using an external controller.

*MX370X_E_050127 1/28/05 8:50 AM Page 8

Advertising