Operating Instructions

Power Up and Boot Sequence

1) Ensure that good batteries are installed in the unit.
2) Simultaneously press and hold the AUDIO and

FREQ buttons until the Power On Boot Sequence is

initiated.

The count will progress from 1

through 3 and the unit will then

power up with the RF output

turned on. During this turn on sequence, the

modulation and power LEDs all glow red, then

green, and then revert to normal operation.

The LCD displays a bootup sequence which con-

sists of four screens:

Company Name:

Lectro

Frequency Block (bXX) and

Firmware Version (rX.X):

b21r1.1 (typ)

Power Level

Pr 250

Compatibility Mode:

CP 400 (typ)

Audio:

Aud 12 (typ)

Power Down

Initial Power Off

Timer Screen

1) Simultaneously press and hold the AUDIO and

FREQ buttons while observing that the word “Off”

appears in the LCD along with a counter.

2) When the counter reaches “0”, the unit turns off.

Note: If the AUDIO and FREQ buttons are

released before the LCD goes blank at the end of

the countdown, the unit will not turn off. Instead, it

will stay energized and the display will return to the

previous screen.

Standby Mode

Standby Screen

With the power turned off,

pressing the AUDIO and

FREQ buttons briefly places

the unit in Standby Mode. In

this mode the RF output is

turned off so all setup adjustments can be made

without interfering with other systems operating in the

same location. The screen displays “rf OFF” to remind

the user that the unit is not transmitting.
While the unit is in the standby mode, access the setup

screens using the AUDIO and FREQ buttons and make

adjustments using the Up and Down arrows.

LCD Backlight Settings

The LCD backlight can be set to turn off after either 5

minutes or 30 seconds or stay on continuously. Hold

the UP arrow in while powering up the unit to enter

the setup screen. Press the AUDIO button repeatedly

to step through the setup items to reach the backlight

settings screen. Use the UP or DOWN arrow button to

select the desired setting.

Selecting the Compatibility Mode

and Output Power

Power setting

400 Series or Digital

Hybrid Wireless™

compatibility mode

The transmitter will work with

200 Series, 100 Series and

IFB analog receivers, plus

some other analog wireless

receivers in addition to the

native digital hybrid mode.

Note: The unit

automatically enters the

Standby Mode when

selecting compatibility.

1) Set the receiver’s audio controls to minimum.
2) From a power off condition, hold down the Up

arrow, then simultaneously press the AUDIO and

FREQ buttons.

3) Press either AUDIO or FREQ button to select the

compatibility screen and use the Up and Down ar-

rows to select the desired mode.

The following Compatibility Modes are available:

• 100 Series mode:

CP 100

• 200 Series mode:

CP 200

• Mode 3

(contact the factory for details):

CP 3

• 400 Series mode:

CP 400

• IFB Series mode:

CP IFB

• Mode 6

(contact the factory for details):

CP 6

4) Press either AUDIO or FREQ button to select the

power setting screen and use the Up and Down

down arrows to select the desired level of power.

5) Simultaneously press the AUDIO and FREQ but-

tons to exit this mode and turn off the power.`

Audio Screen

The Audio screen is used to

adjust input gain from 0 to +44

Advertising