Section 10 - Boiler Controls and Accessory Location

Burner Service Switch

MX BOILER

Figure 11

Figure 12

Boiler Controls and Accessory Location

1.

Remove the top of the boiler jacket. Install
3/4" x 6" relief valve pipe to the top of the
unit as indicated in Fig. 12. Pipe mounts to
the 3/4" hole at the top rear of the boiler
block.

2.

Insert the sensor of the aquastat through the
side of the boiler jacket. Mount the aquastat
to the side of the boiler as indicated in Fig.
11.

3.

Insert 1" to 3/4" reducer to boiler top and
tighten. Insert sensor housing into reducer
and tighten. Insert the sensor into the hous-
ing. NOTE: Sensor must be fully seated for
proper operation.

4.

Replace the top of the boiler jacket.

5.

Attach the pressure relief valve to the previ-
ously attached 3/4" x 6" pipe and tighten.

pressure relief valve

NOTE: Install AFTER
boiler jacket has
been re-installed

aquastat sensor

sensor housing

1” to 3/4 reducer

3/4" x 6" pipe

Aquastat

pressure relief valve

Electrical Junction Box

INSTALLATION MUST BE DONE BY A LICENSED HVAC/HYDRONIC CONTRACTOR
FAMILIAR WITH ALL STATE AND LOCAL CODES.

!