5 lock drive time, 6 time delay of door contact, 7 door contact switch settings – LT Security LTAL5300PM User Manual

Page 29: 8 duress alarm settings

Advertising
background image



Explanation:No passing time zone of validation

unselected time zone number of user,

unselected time zone number of group default time zone

when using group time zone),

the validation time for user does not exist in any setting time zone;

define time zone as forbiddance;

Note:if the time zone set by user is not passed:

□ answer for above combination 2, it appears prompt that user of “Illegal sub-portfolio ” can not open lock, but may check on work

attendance.(in group 4, there are other users meet unlocking qualification, the combination 2 may open the lock)

□ Answer for above combination 1,3,4,5, it appears prompt that user of “Illegal sub-portfolio” can not open lock, but may check on work

attendance.

Note1. when set combination 245, no permission for setting combination 24、combination 25、combination 45.

2. If you want to make all registered users can not unlock, set the whole 10 combinations to empty.


4.3.5 Lock drive time


The lock drive time length means time difference between validated time and starting electric lock that after machine
validates fingerprint. Take 0.5 seconds for the smallest accurate unit. The Largest set is 5s
set to "0" means to close lock control function.


4.3.6 Time delay of door contact


Indicates delay time for inspecting door contact after open the door, namely after delay time to inspect door state (open or
close), if there is difference between the door contact state and the set state, it gives an alarm. This time is the time delay of
door
contact, the unit is “s”


4.3.7 Door contact switch settings


Include three kinds: No, normally opened type, normally closed type;
No: no use of door contact switch;
Normally opened type: if the door is open, the lock should be open, otherwise it shall appear door contact alarm after
passing the delay time;
Normally closed type:

if the door is closed, the lock should be same, otherwise it shall appear door contact alarm after

passing the delay time.


4.3.8 Duress alarm settings



If register duress fingerprint, it shall alarm automatically after passes this fingerprint in

order to prevent somebody from compelling to open the door.


Duress fingerprint management


Register duress fingerprint:Register new fingerprint as duress fingerprint



30

Advertising