Chapter 4

SAN Environments 95

Ch

apter 4

Switch Configuration

HP/Brocade Switch and Interface Manager Configuration

Use the default configuration for the Fibre Channel switch in SAN backup

configurations (see

Figure 18

on page 79).

In this example the:

HP-UX host is attached to ports 1 & 2 of the switch

Windows NT server is attached to port 0

Interface Manager is attached to ports 6 through 15.

Verify that the switch is not using Quick Loop mode.
Use zoning only if it is needed to simplify configuration on the hosts. See the

SAN Backup Solution Configuration Guide referenced at the end of this

chapter for more information.
Two changes should be made when connecting the Interface Manager directly

to a switch port.
Use the Interface Manager’s Fibre Channel Configuration menu:

Set Addressing mode to [Soft]

Set Port Mode to [N_Port]

This provides a direct F_Port to N_Port connection between the switch and

Interface Manager.