Step 1 – HP StorageWorks 1510i Modular Smart Array User Manual

Page 36

Advertising
background image

1.

Select Data Port > Add IP Address.

2.

Enter settings for the data port.

NOTE:

• To control the path of storage traffic to and from the array controller and to add one

level of system security, HP recommends assigning an IP Address to the data port that

is in a different LAN segment than the management port. This IP address can not be

changed. To change an IP address assigned to a port, you must add a new IP address

and then delete the unneeded entry. When deleting an IP address, all corresponding

portals and portal group assignments are also deleted.

• By default, the VLAN ID is 0, meaning that traffic flowing from the port to the switch will

be untagged. To assign a VLAN for this port to use, enter its value. VLANs are set up

on the switch, and are used as one method of controlling access to the storage system.

3.

When the display refreshes, expand (+) all components listed for the Data Port and verify that the

newly added IP address is shown in the component list.