HP StorageWorks 1510i Modular Smart Array User Manual

Page 74

Advertising
background image

8.

In the Management Settings window, enter settings for the management port.

NOTE:

• Port State must be

Enabled

(default) to use the SMU. To re-enable SMU management,

you must use a Command Line Interface (CLI) command. For more information, see

the Command Line Interface user guide.

• Assign a Host Name to the storage system. (Default: chassis serial number)
• By default, the wizard suggests configuring Logical Port Name MA0 as the primary

management port. HP recommends accepting the default.

• To control the path of management traffic to and from the array controller, and to

add one level of system security, HP recommends assigning a static IP address to the

management port

that is in a different subnet than the data ports

. To assign a static IP

address, expand the DHCP Setting drop-down box and change the setting to Disabled.

The page expands (shown), showing the currently assigned IP address. Change this to

the address you want to use for management traffic. After changing the IP address, you

may need to re-connect to the SMU, using the newly assigned IP address.

• VLANs are set up on the switch and are used as one method of controlling access to the

storage. If using VLANs, enter the VLAN ID to use (0 = not used).

74

Wizards

Advertising