background image

4-6

Using the Cross-OS file Exchange Software

Hitachi USP V Cross-OS File Exchange User’s Guide

When FCU starts up, the first set of FCU initiation parameters is automatically
loaded from the specified FCU parameter definition file (unless the file is not

found). If desired, you can change any of the parameters, or you can use the
File-Load command to load the next parameter set. The FCU initiation
parameters are:

Direction. The Direction buttons allow you to select the desired direction
for the FX operation: M to O = FXmto, O to M = FXotm.

Input File. The Input File field allows you to enter the name of the FX
source file. For FXmto, enter the z/OS volser and dataset name
(VSN:dataset). For FXotm, enter the UNIX file name (with complete path if
not in the current directory).

Output File. The Output File field allows you to enter the name of the FX
target file. For FXmto, enter the UNIX file name (with complete path if not in
the current directory). For FXotm, enter the VSN and dataset name
(volser:dataset).

Code Conversion. The Code Conversion buttons allow you to select the
desired code conversion option (see section Code Conversion (CC)
Option):
E<->A = default code conversion table, EcA = default code
conversion table (for FXoto only), No = no code conversion, File = enter the
file name of your conversion table (with complete path if not in current
directory).

Padding. The Padding buttons allow you to select the desired padding
option (see section Padding (PAD) Option): Yes = padding, No = no padding.

Delimiter. The Delimiter buttons allow you to select the desired delimiter
option (see section Delimiter (DEL) Option): CR = carriage return, LF = line
feed, No = no delimiters.

Emp. The Emp buttons allow you to select the empty file option (see section
Empty File (Emp) Option):
Yes = source file is empty, No = source file is not empty.

RDW. The RDW buttons allow you to select the record description word
option (mto only) (see section Empty File (Emp) Option): Yes = add RDW to
each record (Code Conversion, Padding, and Delimiter must be No), No
= do not add RDW to each record.

VSE. The VSE field allows you to enter the VSE record information: RF,RL,BL
Use a comma (no spaces) between each value. See section Record
Description Word (RDW) Option for fu
rther information on the VSE record
option values.

The OK button starts the specified FX operation. The Cancel button removes

the values entered by the user and returns the FCU main panel to the initial
settings. (The Cancel button does not cancel the FX operation in progress.) Be
careful not to click OK or Cancel more than once. The Status field displays

the status of the requested FX operation:

Advertising