Table 32 RAID Manager error codes for Continuous Access Synchronous (SSB1 is

B901/B90A/B90B/B912/D004) (continued)

Description

Error code

(SSB2)

The command was rejected because the volume status is SMPL.

B97C

The pair cannot be created because the consistency group number is greater than is allowed.

B990

If this error occurred when you did not specify the consistency group number, contact HP Technical Support.

The Swap Resync operation cannot be performed because the S-VOL is not in PSUS or SSWS status (Swap
Resync resynchronizes differential data when the S-VOL is swapped for the P-VOL).

B994

The pair cannot be created because the remote system path setting in Remote Web Console is invalid.

B998

The pair cannot be created because Continuous Access Asynchronous is not supported.

B99B

The DKC LDEV configuration might have been changed while starting RAID Manager. Restart RAID Manager.

B9BD

The source of the command device has run out. In LUN Manager, set the command device to OFF, then to
ON.

B9C0

A request for a Pairresync operation was received. The command was rejected because the pair was not
in the Suspend status.

C162

A request for a Pairsplit-S operation was received. The command was rejected because the status change
of the S-VOL failed.

C184

A request for a Pairsplit-S operation was received. The command was rejected because the pair status was
invalid.

C189

A request for a Pairsplit-S operation was received. The command was rejected because the corresponding
volume or group was changing status.

C18A

The pair cannot be split because the S-VOL pair status was in transition.

C194

A request for a Pairsplit-r operation was received. The command was rejected because the pair status was
already PSUS or PSUE.

C195

Pair split cannot be executed because the group includes no pair that can be split.

C198

A request for a Pairsplit-r operation was received. The command was rejected because the corresponding
volume or group was changing status.

C199

The pair’s status cannot be changed during the power-on processing of the DKC.

C1BE

The command was rejected because the specified volume is used for a P-VOL.

C211

The command was rejected because the specified volume is used for an S-VOL.

C212

The command was rejected because the secondary system is not registered, or the registered information
is invalid.

C214

The command was rejected because an internal logical error has occurred.

C215

The command was rejected because the pair status is invalid.

C218

The command was rejected because the P-VOL status is not PSUS, PSUE, or PDUB.

C21A

The command was rejected because the secondary system is not registered, or the registered information
is invalid.

C21C

The command was rejected because the pair release is executed to the volume other than P-VOL.

C22A

The command was rejected because the volume status is SMPL.

C22C

The command was rejected because the specified volume is the volume other than the P-VOL.

C22D

The command was rejected because the pairsplit command specifying -P option (write protection of P-VOL)
was issued to a volume whose status is not PAIR.

C22E

Troubleshooting using RAID Manager