Table 42 – Vaisala WMT700 User Manual

Page 142

Advertising
background image

User's Guide ______________________________________________________________________

Table 42

Required Parameters for WS425 Analog
Output Operation Mode

Parameter Name

Default Value Allowed Values

Description of How to Emulate WS425

aout1err

1000

0 …. 32000

Set 1 for voltage output and 625 for
frequency output for similar operation as
with WS425.

aout1_g

1

0 …. 100

Gain for AOUT1.
Set 0.017895 for compatibility with WS425
voltage output.
Set 11.18 for compatibility with WS425
frequency output.

aout2_g

1

0 …. 100

Gain for AOUT2.
Set 0.0027855 for compatibility with
WS425 potentiometer output.

aout1mode

3

0 = Current
1 = Voltage
2 = Frequency
3 = Disabled

Analog output mode for AOUT1.
Set 1 for WS425 voltage output
compatibility.
2 for WS425 frequency output
compatibility.

aout2mode

7

4 = Current
5 = Voltage
6 = Potentiometer
7 = Disabled

Analog output mode for AOUT2.
Set 6 WS425 potentiometer output
compatibility.

aout1_o
aout2_o

0

-10000 … 10000

Offset for AOUT1 and AOUT2.
Set output offset to 0.

For configuration instructions, see section Configuration on page
110.