Ws425 a/b ascii commands, I — identify sensor, Wx — start measurement – Vaisala WMT700 User Manual

Page 162: Table 50

Advertising
background image

User's Guide ______________________________________________________________________

WS425 A/B ASCII Commands

Table 50 below lists the available commands for operating
WMT700 with the WS425 A/B ASCII profile.

Table 50

WS425 A/B ASCII Commands

Command

Description

I

Requests identification information for WMT700.

Wx

Starts measurement based on averaging time and fetches the data.

NOTE

The following WS425 A/B ASCII command cannot be used with
WMT700: Measurement Unit Change Ux

For a list of configuration commands for WMT700, see Table 63 on page
195.

I — Identify Sensor

This command shows the vendor, model number, and version
information of WMT700.

I

Example of the command and response:

I

VAISALA WMT700 200

Wx — Start Measurement

This command starts wind measurement based on averaging time
and fetches the data automatically when the measurement has
finished. You must specify the averaging time in the command.

Averaging time supplied in the command (x) sets the averaging
time for WMT700, as if it was set with the S command. When
you change the averaging time, it applies to the next new wind
value.

Wx

where

x

= Time for averaging wind speed and wind direction. The range

is from 1 to 9

160 __________________________________________________________________ M211095EN-E