TROUBLESHOOTING

Problem

Possible Cause

Solution

Burners will not light
using the igniter

Burners not assembled cor-
rectly

Not pausing long enough
before clicking the control
panel knob

No spark

LP gas cylinder is empty

Coupling nut is not fully con-
nected to regulator

Excess flow valve tripped in
regulator

Obstructions in burners

Electrodes and burners are
wet

Wire is loose or disconnected

Wire is shorting (sparking
between igniter and electrode

Burners not assembled cor-
rectly

LP gas cylinder is empty

Excess flow valve tripped in
regulator

Coupling nut is not fully con-
nected to regulator

Obstructions in burners

Gas in LP cylinder is low

Excess flow valve tripped in
regulator

See Step 8 - Install Burners of the Assembly Instructions

When lighting the 1st (Leftmost) Burner, push-in and turn con-
trol panel knob counter-clockwise until you feel resistance with
turning. Pause 4 seconds with knob still pushed in, then contin-
ue turning knob counter-clockwise until a click is heard

Gas collector tab is bent (making too large or small of a gap
between electrode and tab). By hand, bend gas collector tab
back within a maximum of 3/16” gap to electrode. (See page 19
for illustration).

Take LP gas cylinder to licensed LP gas supplier to be refilled.

Tighten coupling nut by hand about one-half to three quarters
additional turn. Do not use tools.

Turn control knobs to “off” position and turn LP gas cylinder
handle clockwise until it stops. Wait five minutes. Relight LP
gas grill.

Clean burners (See Burner Maintenance in Care and
Maintenance section of this manual)

Dry electrode with clean cloth.

Reconnect the wire.

Replace igniter wire/electrode assembly (Call the Customer
Service Department).

See Step 8 - Install Burners page of the Assembly Instructions

Take LP gas cylinder to licensed LP gas supplier to be refilled

Turn control knobs to “off” position and turn LP gas cylinder
handle clockwise until it stops. Wait five minutes. Relight LP
gas grill.

Tighten coupling nut by hand about one-half to three quarters

Clean burners (See Burner Maintenance in Care and
Maintenance section of this manual)

Check LP gas cylinder. Refill if necessary.

Turn control knobs to “off” position and turn LP gas cylinder
handle clockwise until it stops. Wait five minutes. Relight LP
gas grill. If flame continues to be low, turn off gas at cylinder
and grill. Disconnect the regulator from the LP gas cylinder.
Reconnect the regulator to the LP gas cylinder. Perform a leak
test. Relight grill. This will reset the excess flow valve.

Burners will not light
using a match

Low flame or low heat