Innovative expertise and drive in the
laboratory sector

T

he demands made on refrigerators and freezers are particularly

high in all the sectors of professional use. Whether the issue is

the refrigeration performance, specifying the materials, designing

the refrigeration components or evolving the design concepts – all

the decisions are directed to ensuring the long-term, trouble-free

use of our appliances.

The most stringent reliability and safety standards apply to appliances

in the laboratory sector. Therefore Liebherr has a range of purpose-

built and factory-designed laboratory appliances in different

temperature ranges for numerous applications. The MediLine

appliances incorporating Profi electronic controllers offer many

advantages. High-grade materials, high-performance components

and accurate workmanship right down to the last detail ensure the

high quality of the Liebherr appliances.

06-07_LaborSpecial_EN.indd 6

11.02.14 13:01

The Profi electronic controller

The menu-guided Profi electronic controller with integrated real-time clock allows the temperature to

be set to 1/10°C accuracy. The text display has German, English, French, Spanish or Italian language

setting options. To satisfy laboratory hygiene requirements, the electronic controller is fl ush-fi tted and

has an easy-clean membrane keypad.

Mains-independent power supply of the electronic controller

In case of power failure, the electronic controller continues to operate from an integrated 12 V battery.

As a result, the memory continues to log the internal temperatures for another 72 hours even in the

event of power failure. Furthermore, if external alarm and documentation systems are connected, the

data transfer is maintained for as long as 72 hours.

Integrated alarm systems

A visual and audible temperature alarm alerts the user if temperature deviation limits are exceeded. In

addition, a visual and audible alarm is activated if the door is open for longer than 1 minute. There is

also an immediate visual and audible alarm in the event of power failure.

Integrated data memory

The Profi electronic controller has an integrated data memory which logs the last 30 alarm events

including date, time and maximum temperature as well as the internal temperature profi le at 4-minute

intervals. 2800 temperature logs are stored to memory, which corresponds to approximately a 7-day

logging period.

3-point calibration

The laboratory appliances with Profi electronic controllers provide 3-point calibration for extremely

accurate temperature control. This permits compensation between the set temperature and the actual

internal temperature at as many as three temperature points. Positive or negative changes to the

correction value can be made in steps of 0.1K.

The laboratory refrigerators and freezers
with Profi electronic controllers

72 hours