background image

IGNITION LEAD

IGNITION CONTROLG
MOUNTING SCREWS

Handle the module at the edges of the board

Do not touch or allow any contact to the module

components, otherwise damage may occur.

1. Disconnect all electrical leads from the ignition

control terminals.

2. Disconnect high voltage ignition lead.

3. Remove ignition control module mounting screws.

See Fig. 10.

FIG. 10

ADAPTER

INLET

BUSHING

GROUND LEAD

VALVE GROUNDING ANDG
ATTACHMENT SCREW

G

ADAPTER

VENTURI G
NECK

BURNER ORIFICE

GAS CONTROLG

VALVE

1. Remove valve grounding and attachment screw.
2. Remove injector body with gas control from venturi

tube.

3. Using a 6 mm hex nut driver, remove the orifice.
4. Clean the orifice hole. Reinstall orifice into the orifice

body. Do not overtighten the orifice as overtightening

can strip the threads in the injector body.

FIG. 11

BURNER ORIFICE

BOOT

SWITCH

1. Disconnect the electrical leads from the ON/OFF

switch.

2. Remove the rubber boot from the ON/OFF switch.

See Fig. 9. Remove the switch from the control box.

FIG. 9

ON/OFF SWITCH

1144

IGNITION MODULE

INJECTOR
BODY