Igniter, High voltage ignition lead, Fig. 13 – L.B. White I-34 Infraconic Spark Ignition User Manual

Page 16: Fig. 14a, Fig. 14b, Fig. 12

Advertising
background image

NUTS

1 Disconnect the ignition lead from the ignitor. Remove

ignitor mounting screws. See Fig. 13.

Fig. 13

2. Remove the igniter from the heater. Clean the rod with

steel wool or emery cloth.

3. The rod and its insulating ceramic body must be rigid

within its mounting flange. If the rod or its body are

capable of movement, the igniter will not be properly

positioned to the combustion cone. The igniter must

then be replaced.

A

Ad

djju

us

sttiin

ng

g IIg

gn

niitto

orr G

Ga

ap

p

Ignitor gap may need to be adjusted if spark is still weak

or non-existent after the ignitor has been either cleaned

or replaced. Refer to the following instructions.

a. Ensure the three burner plate nuts are securely

tightened. See Fig 14a.

FIG. 14a

b. Use gapping tool, part # 23967, to set the gap to .175

inches. See Fig.14b.

FIG. 14b

c. Insert tool at opening between inner and outer

combustion cone tips.

1155

IGNITER

SCREWS

IGNITOR W/ BRACKET

1. Disconnect the igniter lead from ignition module.

2. Loosen the water tight connector nut. See Fig. 12.

Pull the ignition lead through this connection.

3. Disconnect the high voltage ignition lead from the

ignitor. See Fig. 12.

4. Remove the connector nut from the ignition cable.

This nut will be used on the replacement ignition

cable.

5. Although the ignition lead is self locating, ensure it is

positioned away from the venturi tube and the lead

boot is covering the ignitor terminal.

FIG. 12

DISCONNECT FROM

IGNITOR LEAD

LOOSEN NUT

DISCONNECT

IGNITOR LEAD FROM

CONTROL BOX

B

A

C

HIGH VOLTAGE IGNITION LEAD

IGNITOR

TERMINAL

DISCONNECT

LEAD FROM

IGNITION

CONTROL

LOOSEN WATER

TIGHT NUT

DISCONNECT

LEAD FROM

IGNITOR

TERMINAL

GAPPING TOOL

.100

.125

.175

.100 .125

.175

GAPPING TOOL

Advertising