POURING CONDITIONS

ON GRADE

The concrete is poured on the same surface the machine is run on.

BELOW GRADE

The concrete is being poured at a surface lower than what the maĆ

chine runs on.

DROP POUR ADAPTERĆ

When pouring below grade, a drop pour adapter will be needed. A drop

pour adapter will extend the length of the hopper and bolts on similar to

a mold. Additional information is needed in order to manufacture a drop

pour adapter. Adapters can be made either closed or open side and drop

pour depth must be known. Drop pour depths can range from 4" to 10",

after 10" adapter and mold will have to be bolted on in the trench.
Note: There will be an additional charge for drop adapters.

CLOSED SIDE

The side drive unit and mold are at a lower grade than the main unit.

DEPTH

OPEN SIDE

The side drive unit and mold are at a lower grade than the main unit,

but the gutter side of the mold is left open. This allows you to pour up

against existing roadway.

EXISTING

ROADWAY

RUBBER FLAP

MOLD SIDE IS OPEN

DEPTH

Open mold requires

open drop adapter