3 coupling quick-disconnect couplings – Lukas Hydraulic cylinder User Manual

Page 14

Advertising
background image

14

CAUTION!

Always connect the hose to the connection on the cylinder head (cylinder

piston rod side) first and then connect the hose to the connection on the base

of the cylinder!!

For dust protection, the supplied dust caps must be reattached.

WARNING / CAUTION!

To some extent the quick-disconnect coupling have special functions and may

therefore

not be unscrewed from the hydraulic lines and/or swapped!

NOTE:

Hoses can be connected only when

depressurised.

CAUTION!

Always connect the hose to the connection on the cylinder head (cylinder

piston rod side) first and then connect the hose to the connection on the base

of the cylinder!!

Before coupling, remove the dust caps then pull back and hold the locking sleeve on the

female half (position X). Plug the male and female halves together and release the locking

sleeve. Then turn the locking sleeve to position Y. The connection is now made and secured.

Uncoupling is carried out in the reverse sequence. Hoses can be connected only when

depressurised. For dust protection, the supplied dust caps must be reattached.

6.3 Coupling Quick-disconnect Couplings

The cylinder is connected to the hydraulic pump via Quick-disconnect coupling halves (male

and female).

X

Y

Advertising