8. Dismantling the equipment / deactivation following

operation

WARNING / CAUTION!

Before dismantling the used equipment, you must ensure that the load being

moved is in a stable, non-slip location!

8.1 Hydraulic cylinder

After the work is completed the hydraulic cylinders should be retracted to leave just a few

mm

*)

protrusion (up to the end position on single acting cylinders). This relieves the hydraulic

and mechanical strain on the device.

NOTE:

When hydraulic cylinders are in storage, fluctuations in ambient temperature can

cause the pistons to move slightly. This phenomenon is due to the difference in

the expansion of the hydraulic fluid on the piston side and the rod side.

*)

1 mm = 0.04 in.

8.2 Hydraulic unit

8.3 Hoses

Upon completion of work, the unit must be deactivated.

Uncoupling is carried out in the reverse order, as described in Chapter “Connecting the

Equipment”.

Ensure that you replace the dust protection caps on the Quick-disconnect coupling halves.