Schematic diagram of injector manifold point of installation with “Hartford loop”

DETAILS OF VENTURI INJECTOR MANIFOLD:

Attention: Install venturi with bypass valve on water recirculation pipeline. Arrow on venturi

MUST be set as the same direction as water flow.

Turn water pump on and close the by- pass valve until vacuum is created at venturi input.

Note1: Use the installed flow-meter to check vacuum -2 to -3 PSI (-0.14 to -0.21 bars) or place

finger over end of venturi valve to feel vacuum while adjusting the by-pass venturi valve. At this

point, the air is injected into the water line; you will observe the air as bubbles in the water of

the swimming pool.

MAIN POWER:

Use the power cable provided to connect the SP-Series to a properly rated and

grounded receptacle. If the ozone generator will be used where water is present, a

ground fault circuit interrupter must protect the circuit.