INSTRUCTION SHEET
Hydrostik Hydrogen Fuel Cylinder
PN 074-626-P1A
2 of 7
Fill Hydrostik with Hydrogen
Hydrostik must be filled with hydrogen before it is connected to either
DataFID or MicroFID II. Once filled with hydrogen, Hydrostik (with Hydrostik Adapter)
can be installed into the DataFID or MicroFID II through a Swagelok
®
connection.
Tools Required
1 1/18” open-ended wrench, for CGA350 fitting
NOTE: If using an international version of the filling station, the wrench size will depend
on the fitting from the filling station to the hydrogen supply tank.
Procedure
WARNING
Do not fill Hydrostik in a hazardous location.
WARNING
Use only Hydrogen Fill Station PN A1201222
to fill Hydrostik.
WARNING
The regulator pressure on the Hydrogen Fill Station is preset
at the factory to 250 PSI. Do not change this setting.
WARNING
Handle the high pressure hydrogen supply tank
with extreme caution.
WARNING
Before using the hydrogen fill station, make sure that the
fitting connecting the hydrogen supply tank has been
leak-checked.