Global drive cam loader – Lenze Global Drive Cam Loader User Manual

Page 16

Advertising
background image

Global Drive Cam Loader

Introduction

Creating/preparing import data

16

1.1 EN - 05/2005

L

Cam type
The cam type is defined through the following numbers:

Entry

Cam type

1

Position cam in positive effective direction

• Switch on and switch off point are defined by positions.

• The cam switches if the direction of the axis is positive (positive speed).

2

Position cam in negative effective direction

• Switch on and switch off point are defined by positions.

• The cam switches if the direction of the axis is negative (negative speed).

3

Position cam with bipolar effective direction

• Switch on and switch off point are defined by positions.

• The cam switches in positive and negative direction of the axis.

11

Time-based cam in positive effective direction

• The cam switches on at the switch on point if the direction of the axis is positive (positive speed).

• After the selected time, the cam switches off.

12

Time-based cam in negative effective direction

• The cam switches on at the switch on point if the direction of the axis is negative (negative

speed).

• After the selected time, the cam switches off.

Advertising