Error numbers, causes & remedies

D401h

Error during the start of the "DriveLC7" com-

ponent.

• Component has not been installed or has

not been registered correctly.

Re-install Cam Loader.

D402h

Error during setting the cam profile data

(points).

Evaluate error description.

D405h

Error during writing the LC7 file.

Check path for the LCx file.

Check if there is enough free space available

on your drive.

Errors within the DriveServer
E7C18000

Error during download preparation.

Repeat download.

E7C18001

PLC has not stopped.

Stop the PLC program in the target system.

E7C18002

Controller inhibit has not been set.

Set controller inhibit in the target system

(e.g. via terminal 28 or code C0040).

E7C18003

Incorrect data type (no LC9 file).

Create new LC9 file.

E7C18004

Check sum test is negative (faulty check

sum).

Repeat download.

Increase time-out time in the system bus

configuration tool (e.g. to 3 seconds).

E7C18005

Item can momentarily not be accessed due to

download.

Repeat download after a few minutes or re-

start your PC.

E7C18006

Target system is momentarily busy copying

RAM blocks.

Start the PLC program in the target system.

E7C18007

Error occurred after the download.

Repeat download.

E7C18008

Error after version comparison during down-

load of an LC7 file.

• Different versions in LC7 file and target

system.

Update the operating system of the 9300 EK.

E7C18009

No template "Cam" in the target system.

Create DDS project based on Template Cam

and transfer it into the target system.