72 — CONSTRUCTION MASTER

PRO

Jack Rafters — Using Other Than 16 Inch On-Center
Spacing (not available on LT
)

A roof has a 9/12 pitch and a run of 6 feet 9 inches. Find the Jack raf-

ter lengths and cut angles at 18-inch (versus 16-inch) on-center

spacing.

Keystroke

Display

1. Enter pitch, run and spacing:

[On/C] [On/C]

0.

9 [Inch] [Pitch]

PTCH 9 INCH

6 [Feet] 9 [Inch] [Run]

RUN 6 FEET 9 INCH

18 [Inch] [Stor] [7]

OC 18 INCH


2. Find Jack rafter lengths and cut angles:

[Jack]

JKOC 18 INCH

[Jack]

JK1 6 FEET 6-3/4 INCH

[Jack]

JK2 4 FEET 8-1/4 INCH

[Jack]

JK3 2 FEET 9-3/4 INCH

[Jack]

JK4 0 FEET 11-1/4 INCH

[Jack]

JK5 0 FEET 0 INCH

[Jack]

PLMB 36.87

°°

[Jack]

LEVL 53.13

°°

[Jack]

CHK1 45.00

°°