Table 1 - Head communication DIP switch settings (8)

SW1

SW2

SW3

SW4

SW5

SW6

SW7

SW8

HS102, HS105

(2400)

OFF

OFF

OFF

ON

OFF

OFF

HS2010

ON

OFF

ON

OFF

OFF

OFF

HS310 (9600)

ON

OFF

ON

OFF

OFF

OFF

HS102 (19K2)

ON

OFF

OFF

OFF

OFF

OFF

SP2000 X/Y

ON

OFF

ON

OFF

OFF

OFF

Quattro Z

ON

OFF

ON

OFF

OFF

OFF

SP300 X/Y

ON

OFF

ON

OFF

OFF

OFF

Radamec

OFF

OFF

ON

OFF

ON

OFF

Normal zoom

OFF

Reverse zoom

ON

Normal focus

OFF

Reverse focus

ON

Table 2 - Lens communication DIP switch settings (9)

Switch

Position

Motion

Control

Coms

Speed

Notes

0

Velocity

-

Revert to original software version

1

Positional

240 Hz

-

2

Positional

120 Hz

Factory default setting

3

Positional

60 Hz

-

4–F

-

-

Not in use

Note:

If the camera lens response is inadequate, experiment with the other three possible rotary
DIP switch positions (9) to achieve satisfactory control.

None of the control settings will harm the lens.