Dtc-379 c2xpress – DekTec DTC-379 C2Xpress User Manual

Page 13

Advertising
background image

© 2010 - 2015 DekTec Digital Video BV

Page 13/18

DTC-379 C2Xpress Manual

Essential Tools for Digital-TV Professionals

February 2015

DTC-379 C2Xpress

PLP parameter

Description

PLP ID

Unique identification of a PLP within a C2 system

Bundled

Indication whether the PLP is bundled with other PLPs within the C2 System.

If checked, the PLP is bundled with PLP(s) in other Data Slice(s) (having the

same PLP ID)

Type

PLP Type: Common PLP, Grouped Data PLP or Normal Data PLP

Group ID

PLP Group ID. Identifies the PLP group with which the PLP is associated. This

parameter is not used when the PLP type is Normal Data PLP

Modulation

Modulation type used by the PLP:16-QAM, 64-QAM, 256-QAM, 1024-QAM

or 4096-QAM

Code rate

Code rate used by the PLP: 2/3, 3/4, 4/5, 5/6, 8/9 (16K LDPC) or

9/10(64K LDPC)

ACM test

Displays the number of modulation and coding parameter settings defined

for Adaptive Code and Modulation (ACM) testing. This is only available for

type 2 Data Slices.

If no settings are defined for ACM testing, ACM testing is disabled and the

modulation and coding parameters from the PLP-parameter page are used.

If one or more settings are defined for ACM testing, ACM testing is enabled.

Successive XFEC frames of the PLP use the modulation and coding

parameter setting from the ACM-testing list. After the last parameter setting

from the list is used, the first setting is used again.

When double clicking on the ACM test field, a dialog is opened that allows

you to specify the PLP modulation and coding parameters for ACM testing.

By a right mouse click you can add or remove entries.

Per entry you can specify the FEC Type, Modulation, Code rate, Header

Counter and the number of XFEC frames using these parameters.

FEC

FEC type used by the PLP: 16K LDPC or 64K LDPC

HEM

High Efficiency Mode / Normal Mode selection. If checked, the PLP uses

High Efficiency Mode

ISSY

Input Stream Synchronization mechanism: None, Long (=3byte) or Short

(=2byte) field

BUFS

Maximum size of the requested receiver buffer to compensate for delay

variations. This variable uses the ISSY field and therefore it is only enabled if

the ISSY field is used

Output Delay

Delay (in T units) between the incoming data and the output TS in the

receiver model.

NPD

Null Packet Deletion. If checked, the PLP uses Null Packet Deletion

CCM

CCM/ACM flag (Constant Coding and Modulation or Variable/Adaptive

Coding and Modulation). If checked, CCM is signalled, otherwise ACM.

Header Counter

Number of FECFrames following the FECFrame header: 1 or 2 FECFrames

PSI/SI Reproc

Indication whether the PSI/SI is reprocessed or not. If checked, this indicates

that the PSI/SI is reprocessed and the receiver can rely on the PSI/SI

information

TS ID

Transport Stream ID that serves as a label for the identification of this TS

from any other TS within the C2 System. This is used when the PSI/SI is not

Advertising