DTC-379 C2Xpress

reprocessed

Onw ID

Gives the Original Network ID. This is used when the PSI/SI is not

reprocessed

Source

Displays the selected source. When double clicking on the source, a dialog is

opened that allows you to select the source.

The source of a PLP can be:

(a) 0151 PRBS test signal

The PID has to be specified and optionally null packet insertion can be

enabled (Q>0). If null packet insertion is enabled, P specifies the number of

non-null packets and Q specifies the number of null packets in a sequence

of Transport Stream packets. In case the scheduling method Dynamic is

selected, the bitrate has to be specified too.

(b) Transport Stream file

The path of the Transport Stream can be selected. If possible the bitrate is

estimated automatically.

Four different modes of Transport Stream insertion are supported:

i)

Complete Stream

The complete Transport Stream file is included in the PLP.

ii)

Partial Stream Data Extraction

One service from the Transport Stream file has to be selected;

the related data is extracted and included in the data PLP. The

included data comprises the service components, a PAT, an SDT-

actual and the PMT-table.

iii)

Partial Stream Common Extraction

All common data related to the selected services in the same PLP

group is extracted from the Transport Stream file and included in

the common PLP. This common data is co-timed with the data in

the data PLPs.

(c) No data

No data is provided for this PLP. This option has to be selected if the PLP has

to be present in the L1 part2 signalling but without carrying data.

To add more PLPs, right-click the mouse in PLP parameter row below the Data Slice to which the

new PLP will be added and select: Insert PLP. Alternatively, the Insert key can be used.
To remove a PLP, select the PLP then right-click the mouse and select: Remove PLP. The shortcut key

in this case is Delete.
To navigate through the PLP parameters, use the arrow keys. After selection you can press the Enter

key to modify the parameter. When done, press the Enter key for further navigation.

7.7. Notch Parameters
The Notch tab allows you to specify the Notch bands within the C2 Frame.
Each row specifies the parameters for one Notch band.