Advanced option menu – DynaScan 46″ Video Wall Super Narrow Bezel LCD DS46LX2 User Manual

Page 30

Advertising
background image

21

EXIT

MENU

:SEL

+-:ADJ

:RETURN

:EXIT MENU

SCREEN SAVER

COOLING FAN

BRIGHTNESS
MOTION

AUTO

OFF
OFF

• {

COOLING FAN} - Select {ON} to turn on the cooling fan

all the time. Select {

AUTO} to turn on/off the cooling fan

according to the display’s temperature.
NOTES:
• The default {

AUTO} option will start running the cooling

fan if the temperature of

65°C (152°F) is reached, and

will keep running for

30 minutes after cooling down to the

temperature of

62°C (144°F).

• A temperature-warning message will be shown on the

screen once the temperature reaches

79°C. All key

function except [

Power] key will then be disabled.

• {

BRIGHTNESS} - Select {ON} and the brightness of

the image will be reduced to an appropriate level, and

the Brightness setting in the Picture menu will become

unavailable.

• {

MOTION} - Select the time interval ({10 ~ 900} Seconds /

{

OFF}) for the display to slightly expand the image size and

shift the position of pixels in four directions (up, down, left, or

right).

SIDE BORDER COLOR
Adjust the brightness of the black areas displayed on both sides

of 4:3 images.
CONFIGURATION3 RESET
Reset all settings in the

CONFIGURATION3 menu to factory

preset values.

4.2.8. ADVANCED OPTION menu

PIP

1
2
3

SET

EXIT

MENU

:SEL

:NEXT

INPUT CHANGE

TERMINAL SETTING

SCAN CONVERSION

COLOR SYSTEM

SCAN MODE

SERIAL CONTROL

LAN SETTING

ADVANCED OPTION RESET

FACTORY RESET

ADVANCED OPTION

:RETURN

:EXIT MENU

NORMAL

LAN

INPUT CHANGE
Select the time for input switching as {

NORMAL} or {QUICK}.

NOTE: The selection {

QUICK} may cause a slight noise.

TERMINAL SETTING
Select the mode to display the HDMI or DVI signal according to

their signal format depending on their source device.

• {

DVI MODE}: Used for DVI-D signal.

• Select {

DVI-PC} when the source device is a PC.

• Select {

DVI-HD} when the source device is a video

device.

• {

HDMI SIGNAL}: Used for HDMI signal.

• Select {

LIMITED} when displaying the signal that uses

16 to 235 levels of 256 levels for each R, G, and B.

• Select {

FULL} when displaying the signal that uses all

256 levels (from level 0 to 255).

PIP

1
2
3

EXIT

MENU

:SEL

+-:ADJ

DVI-MODE

HDMI SIGNAL

TERMINAL SETTING

:RETURN

:EXIT MENU

DVI-PC

FULL

SCAN CONVERSION
Choose to enable or disable the IP (Interlace to Progressive)

conversion function.
• {

PROGRESSIVE} - Enable the IP conversion function

(recommended). Once enabled, the interlace input signal will

be converted to progressive format for better display quality.

• {

INTERLACE} - Disable the IP function. This mode is

suitable for displaying motion pictures, but it increases the

chance of image retention.

COLOR SYSTEM
Selects the Color System depends on your input video format.
The options are: {

AUTO} / {NTSC} / {PAL} / {SECAM} /

{

4.43NTSC} / {PAL-60}.

NOTE: This item is functional for

S-VIDEO or VIDEO input

only.

SCAN MODE
Change the display area of the image.
• {

OVERSCAN} - Display about 95% of the original size of the

image. The rest of the areas surrounding the image will be

cut off.

• {

UNDERSCAN} - Display the image in its original size.

NOTE: This item is functional for

HDMI-Video timing input

only.

SERIAL CONTROL
Select the nectwork control port.
The options are: {

RS-232C} / {LAN}.

NOTE: If {

LAN} is selected, then {RS-232C} will not be

activated, even if a cable is attached, and vice versa.

LAN SETTING
Assign {

IP ADDRESS}, {SUBNET MASK}, and {DEFAULT

GATEWAY} for the display.

DS32CR \DS42CR \DS46CR \DS46LX Series

Advertising