Regulation of air supply to oven and grill burners – Caple CRG902SS User Manual

Page 16

Advertising
background image

16

Fig. 3.10

Fig. 3.11

Regulation of air supply to
oven and grill burners

Using a cross-head screwdriver, slacken
the screw securing the air flow
regulation collar (fig. 3.10 and 3.11) and
move the collar forward or backward to
increase or reduce the air aperture in
accordance with gas type and the
indications in the “TABLE FOR THE
CHOICE OF THE INJECTORS”.
Light the burner and check the flame.

Ring opening

Advertising