7.4

Serial Control

7.4.1

Telegram Structure

Command

<STX>, <command byte (CMD)>, [data bytes (D0…DN)], <ETX>

[ ] = Optional elements

Response

<ACK> , [<ECHO>]

[ ] = Optional elements

<ECHO> reports the matrix sequences solicited by a command and thus
the new switching status of the matrix. The echo can be used to update
user applications and to operate several matrices in parallel.

Parameter Description

Command byte:

In the range 0x40 to 0x6F

(see list of allowed commands below)

Data bytes:

a) Binary data:

In order to prevent that, during the

transmission of binary data, control statements of

control commands are transferred, the data are

divided into low-nibble and high-nibble. The data

are distributed to the low-nibbles of two bytes and

provided with an offset by 0x60 e.g. 0x1F

=> 0x61 + 0x6F

b) 7bit data:

(0x0 to 0x7F) are provided with an

offset by 0x80, e.g. 0000011 => 0x83

c)

ASCII

data

=> 0x20 to 0x7E are transmitted

unencryptedly.