Protocol, Set-function listing – VIEWSONIC ViewBoard IFP8662 86" 4K Interactive Display User Manual

Page 109

Advertising
background image

109

Protocol

Set-Function Listing

The PC can control the Display for specific actions. The Set-Function command

allows you to control the Display behavior at a remote site through the RS232 port.

The Set-Function packet format consists of 9 bytes.

Set-Function Description:

Length:

Total Byte of Message excluding “CR”

LFD ID

Identification for each of Display (01~98; default is 01)

ID “99” means to apply the set command for all connected

displays. Under such circumstances, only ID#1 display has to

reply.

The LFD ID can be set via the OSD menu for each Display.

Command Type

Identify command type,

“s” (0x73h): Set Command

“+” (0x2Bh): Valid command Reply

“-“ (0x2Dh): Invalid command Reply

Command:

Function command code: One byte ASCII code.

Value[1~3]:

Three bytes ASCII that defines the value.

CR

0x0D

Set-Function Format
Send: (Command Type=

s”)

Name

Length

ID

Command Type Command

Value1 Value2 Value3 CR

Byte

Count 1 Byte

2

Byte

1 Byte

1 Byte

1 Byte 1 Byte 1 Byte

1

Byte

Bytes

order

1

2~3

4

5

6

7

8

9

Reply: (Command Type=“+” or “-”)

Name

Length

ID

Command Type

CR

Byte

Count

1 Byte 2 Byte

1 Byte

1 Byte

Bytes

order

1

2~3

4

5

NOTE: 

When PC applies command to all displays (ID=99), only the #1 set needs

to reply by the name of ID=1.