Remote Control Pass-through Mode

When the PC sets the Display to Remote Control Pass through mode, the Display

shall send a 7-byte packet (followed by “CR”) in response to remote control unit

(RCU) button activation. In this mode the remote control shall have no effect on

the Display function. For example: “Volume+” will not change the volume of the

Display, but instead only sends the “Volume+” code to the PC over the RS232 port.

IR Pass Through-Function format
Reply: (Command Type=“p”)

Name

Length

ID

Command Type

RCU Code1

(MSB)

RCU Code2

(LSB)

CR

Byte

Count 1 Byte

2

Byte

1 Byte

1 Byte

1 Byte

1 Byte

Bytes

order

1

2~3

4

5

6

7

Example 1: Remote Control Pass-through when “VOL+” key is pressed for Display

(#5)
Send (Hex Format)

Name

Length

ID

Command Type

RCU Code1

(MSB)

RCU Code2

(LSB)

CR

Hex

0x36

0x30

0x35

0x70

0x31

0x30

0x0D

Key

Code (HEX)

Basic

*3.1.1

Optional

*3.1.1

1

01

V

2

02

V

3

03

V

4

04

V

5

05

V

6

06

V

7

07

V

8

08

V

9

09

V

0

0A

V

-

0B

V

RECALL (LAST)

0C

V

INFO (DISPLAY)

0D

V

0E

ASPECT (ZOOM, SIZE)

0F

V

VOLUME UP (+)

10

V

Advertising