Get-Function Listing

The PC can interrogate the LFD for specific information. The Get-Function packet

format consists of 9 bytes which is similar to the Set-Function packet structure.

Note that the “Value” byte is always = 000.

Get-Function Description:

Length:

Total Byte of Message excluding “CR”.

TV/DS ID

Identification for each of TV/DS (01~98; default is 01).

Command Type

Identify command type,

“g” (0x67h) : Get Command

“r” (0x72h) : Valid command Reply

“-“ (0x2Dh) : Invalid command Reply

Command:

Function command code: One byte ASCII code.

Value[1~3]:

Three bytes ASCII that defines the value.

CR

0x0D

Get-Function Format
Send: (Command Type=“g”)

Name

Length

ID

Command Type Command

Value1 Value2 Value3 CR

Byte

Count 1 Byte

2

Byte

1 Byte

1 Byte

1 Byte 1 Byte 1 Byte

1

Byte

Bytes

order

1

2~3

4

5

6

7

8

9

Reply: (Command Type=“r” or “-”)

If the Command is valid, Command Type = “r”

Name

Length

ID

Command Type Command

Value1 Value2 Value3 CR

Byte

Count 1 Byte

2

Byte

1 Byte

1 Byte

1 Byte 1 Byte 1 Byte

1

Byte

Bytes

order

1

2~3

4

5

6

7

8

9

If the Command is NOT valid, Command Type = “-”

Name

Length

ID

Command Type

CR

Byte

Count

1 Byte 2 Byte

1 Byte

1 Byte

Bytes

order

1

2~3

4

5