Laser safety label reproduction, Laser emission data, Laser compliance statement – CHAUVET DJ GigBAR Move + ILS 5-in-1 Lighting System with Moving Heads, Pars, Derbys, Strobe, and Laser Effects User Manual

Page 13: Before you begin laser safety label reproduction, Laser exposure warning, Page 7, Gigbar move + ils user manual rev. 3

Advertising
background image

Page 7

GigBAR MOVE + ILS User Manual Rev. 3

Before You Begin

Laser Safety Label Reproduction

Laser Exposure Warning

Laser Emission Data

As measured under IEC measurement conditions for classification.

Laser Compliance Statement

Complies with FDA performance standards for laser products except for deviations pursuant to Laser

Notice No. 56, dated May 08, 2019. No maintenance is required to keep this product in compliance with

laser performance standards.

LASER LIGHT AVOID DIRECT EYE EXPOSURE

Further guidelines and safety programs for safe use of lasers can be found in the ANSI Z136.1

Standard “For Safe Use of Lasers”, available from the Laser Institute of America:

www.lia.org

.

Many local governments, corporations, agencies, military, and others, require all lasers to be

used under the guidelines of ANSI Z136.1. Laser Display guidance can be obtained via the

International Laser Display Association:

www.ilda.com

.

Laser Classification

Class 3R

Red Laser Medium

LD/638 nm/30 mW

Green Laser Medium

LD/520 nm/20 mW

Blue Laser Medium

LD/450 nm/50 mW

Beam Diameter

<5 mm at aperture

Pulse Data

All pulses < 4 Hz (>0.25 sec)

Divergence (each beam)

<2 mrad

Divergence (total light)

<160 degrees

Laser Power of Each Beam from Aperture*

<5 mW

*As measured under IEC measurement conditions for classification.

LASER APERTURE

MODEL:

GIGBARMOVE+ILS

ITEM CODE:

10051946

FUSE:

T 3.15 A, 250 V

POWER LINKING:

8 A

(2 UNITS @ 120 V)

(4

UNITS

@

230

V)

ORIGIN:

MADE

IN

CHINA

USA / CANADA
POWER: 100-125 VAC, 60 Hz
3 A, 250 W

WORLDWIDE
POWER: 100-240 VAC, 50/60 Hz
1.8-3 A, 248 W

THIS APPLIANCE MUST BE GROUNDED
CETTE UNITÉ DOIT ÊTRE RELIÉE À LA TERRE
USE ONLY FUSE OF SAME TYPE & RATING
N’UTILISER QUE DES FUSIBLES DU TYPE ET
DE L’AMPÉRAGE INDIQUÉ
NOT FOR HOUSEHOLD USE
IMPROPRE A L’USAGE DOMESTIQUE
DRY LOCATIONS
EMPLACEMENTS SECS
DISCONNECT POWER BEFORE SERVICING
DÉBRANCHER AVANT TOUT ENTRETIEN
FOR INDOOR USE ONLY
USAGE INTÉRIEUR UNIQUEMENT

WORLDWIDE HEADQUARTERS,

SUNRISE, FLORIDA USA

450/520/638nm

CW, <5mW

WARNING

Cancer and Reproductive Harm -

www.P65Warnings.ca.gov

IEC/EN60825-1:2014

!"#$%&'(

RoHS