The load is coupled with a 2 pitch lead screw. A 2000 count/rev encoder is on the motor, resulting in a
resolution of 4000 counts/inch. The program below uses the variable len, to length. The IN command
is used to prompt the operator to enter the length, and the entered value is assigned to the variable
LEN.

Instruction Interpretation

#BEGIN LABEL
AC 800000

Acceleration

DC 800000

Deceleration

SP 5000

Speed

len=3.4

Initial length in inches

#CUT Cut

routine

AI1

Wait for start signal

IN "enter Length(IN)", len

Prompt operator for length in inches

PR LEN *4000

Specify position in counts

BGA

Begin motion to move material

AMA

Wait for motion done

SB1

Set output to cut

WT100;CB1

Wait 100 msec, then turn off cutter

JP #CUT

Repeat process

EN End

program

Operator Data Entry Mode

The Operator Data Entry Mode provides for un-buffered data entry through the auxiliary RS-232 port.
In this mode, the DMC-2x00 provides a buffer for receiving characters. This mode may only be used
when executing an applications program.

The Operator Data Entry Mode may be specified for Port 2 only. This mode may be exited with the \
or <escape> key.

NOTE: Operator Data Entry Mode cannot be used for high rate data transfer.

Set the third field of the CC command to zero to set the Operator Data Entry Mode.

To capture and decode characters in the Operator Data Mode, the DMC-2x00 provides special the
following keywords:

Keyword Function

P2CH

Contains the last character received

P2ST

Contains the received string

P2NM

Contains the received number

P2CD

Contains the status code:
-1 mode disabled
0 nothing received
1 received character, but not <enter>
2 received string, not a number
3 received number

NOTE: The value of P2CD returns to zero after the corresponding string or number is read.