Table 13-41. aupc parameter oids, Aupc p – Mocomtech CIM-550 User Manual

Page 278

Advertising
background image

CiM-550 IP Enabled Satellite Modem

Rev. 2

SNMP interface

CD/CIM550.IOM

252

13.5.1.6 T

HE

“”AUPC P

ARAMETERS

Table 13-41. AUPC Parameter OIDs

OID Description

cim550AupcEnable

Enables or disables AUPC (Automatic Uplink Power
Control). Can be set to:

0 Disable

1 Enable

cim550AupcControlParameters

Defines AUPC (Automatic Uplink Power Control)
operating parameters. Has the form abc.cd Where: a =
Define action on max power condition: 0 = do nothing 1
= generate TX alarm b = Define action on remote
demod unlock: 0 = go to nominal power 1 = go to max
power c.c = Target Eb/No value, in dB, for remote
demod d = Maximum increase in Tx Power permitted, in
dB

cim550RemoteEbno

Returns the value of Ebi/No of the remote demod, if
Framing is enabled. Returns 999 if demod is unlocked.
Returns -1 if Framing is not enabled. Ebi/No values can
be between 20 and 60 in 0.1 dBs where 20=2.0 dB to
160=16.0 dB.

cim550TxPowerLevelIncrease

Returns the increase in Tx power level, in dB (from the
nominal setting) due to the action of AUPC. Returns –1
if AUPC is not enabled. Values can be between 0 and
90 in 0.1 dBm where 0 = 0.0 dBm to 90 = 9.0 dBm

Advertising