0 technical data – Maytag Ventilation Systems HRV-210 User Manual

Page 11

Advertising
background image

11

Model numbers:

• ERV-150
• HRV-150

Model numbers:

• ERV-210
• HRV-210

13-3/4" (349mm)

20" (508mm)

(50

0"

6" (152mm)

2.5" (63mm)

30-1/4" (768mm)

VK0040

4.4

D

IMENSIONS

4.0

Technical Data

(cont’d)

19" (483mm)

20" (508mm)

08m

(50

6" (152mm)

30-1/4" (768mm)

2.5" (63mm)

VK0039

Main controls:
• Basic Wall Control
• Electronic Wall Control

Optional control:
• 20/40/60-minute push button

Link option:
• Furnace interlock (use with

forced air systems)

4.5

C

ONTROLS AND

F

URNACE

L

INK

O

PTION

4.6

S

PECIFICATIONS

Model numbers

Weight

Port Diameter

Drain Diameter

ERV-150, HRV-150

65 lb (30 kg)

6” (152 mm)

1/2” (12 mm)

ERV-210, HRV-210

73 lb (33 kg)

6” (152 mm)

1/2” (12 mm)

Installation

Chains, springs and hooks (provided with the unit).

Motor Speed

High and low speeds factory set (optional increased low speed - BLUE wire).

Electrical supply

120 V, 60 Hz

120 V, 60 Hz

Power Consumption

150 Watts

225 Watts

Advertising
This manual is related to the following products: