0 installation – Maytag Ventilation Systems HRV-210 User Manual
Page 19
19
6.7 I
NSTALLING THE
E
XTERIOR
H
OODS
6.0
Installation
(cont’d)
Choose an appropriate location for
installing the exterior hoods:
•
a minimum distance of 6 feet (1.8 m)
between the hoods to avoid
cross-contamination
•
a minimum distance of 18 inches (457 mm)
from the ground
Make sure the intake hood is at least 6 feet
(1.8 m) away from any of the following:
•
dryer exhaust, high efficiency furnace
vent, central vacuum vent
•
gas meter exhaust, gas barbecue-grill
•
any exhaust from a combustion source
•
garbage bin and any other source of
contamination
Refer to figure 15 for connecting the insulat-
ed duct to the hoods. Place the “FRESH
AIR INTAKE” sticker, provided in the instal-
lation kit, on corresponding hood. An “Anti-
Gust Intake Hood” should be installed in
regions where a lot of snow is expected to
fall.
CAUTION
All models require an exhaust hood with a backdraft damper. This damper closes when the unit is
off and prevents unwanted cold air from entering the house.
VD0028
Exhaust
hood
Optional duct
location
Tape and duct tie
Caulking
Intake
hood
6ӯ
(152 mm)
18”
(457 mm)
18”
(457 mm)
6’
(1.8 m)
6’
(1.8 m)
18”
(457 mm)
figure 15
6.8 C
ONNECTING THE
D
RAIN
12"(305 mm)
VO0004
VO0003
Attach the 2 plastic drain fittings
to the unit using the gaskets,
washers and nuts as shown.
Cut 2 sections of plastic tubing,
about 12” (305 mm) long and
attach them to each drain fitting.
1
2
VO0005
Join the 2 short sections to the “T”
junction and main tube as
shown.
3
VO0011
To drain
Tie-wrap
4
Make a water trap loop in the tube to prevent the unit from drawing
unpleasant odors from the drain source. Make sure this loop is
situated BELOW the “T” as shown. This will prevent water from
being drawn back up into the unit in case of negative pressure. Run
the tube to the floor drain or to an alternative drain pipe or pail. Be
sure there is a slight slope for the run-off.