0 wiring diagram, Connection logic, Warning – Maytag Ventilation Systems HRV-210 User Manual

Page 25

Advertising
background image

25

9.0

Wiring Diagram

A1

M1

M2

K1

RELAY

K2

RELAY

K5

RELAY

FAN

MOTOR

DAMPER

MOTOR

NEUTRAL

MED

NC

HIGH

LOW

J1 6

J1 3

J1 4

J1 9

K4

RELAY

J3 1

J3 2

FURNACE BLOWER INTERLOCK

CLASS 2 CIRCUIT ONLY

ELECTRONIC ASSEMBLY

S1

120V 60Hz

FROM MAIN

J1 2

J1 1

J1 8

VE0018A

BK

G

R

Y

R

BK

Y

NOTE 4

WALL CONTROL

WALL CONTROL

WALL CONTROL

WALL CONTROL

OVERRIDE SWITCH

OVERRIDE SWITCH

OVERRIDE LED

FURNACE BLOWER

INTERLOCK

NOTES 1, 5

NOTE 5

OPTIONAL

NOTES 5, 6

OPTIONAL

M1

X2

M2

1

2

1

1

2

3

1

2

4

7

6

9

3

4

5

6

7

8

9

2

3

1

2

NEUTRAL

MEDIUM

HIGH

LOW

FAN MOTOR

X1

GY

O

G

BL

R

GY

O

G

NC

R

(NOTE 2)

BN

BN

C1

BL

BL

DAMPER

MOTOR

MAIN EARTHING

POINT

R

O

GY

W

T1

R1

A1

DEFROST

TEMPERATURE

SENSOR

JU1

J4

J1

J3

ABCDEFG

F

F

IO

CO

LY

RG

B

ELECTRONIC ASSEMBLY

Y

BL

BL

Y

COM

120V 60 Hz

W1

G

BK

W

NEMA-15P

5-15 PLUG

BK

DOOR INTERLOCK

SWITCH S1

NO

NEUTRAL

LINE

BK

VE0037A

-t

°

Models: ER

V

-150, HR

V

-150,

ER

V-210, HR

V-210

NOTES

1-

Controls available. See Section 8.0 (Low voltage only

, 12VDC)

2-

The factory set wiring for blower speed selection is high and low

.

Medium speed can be selected instead of low speed. Disconnect the

RED wire from the motor RED tap and connect it to the motor BLUE tap.

3-

If any of the original wire, as supplied, must be replaced, use the

same or equivalent wire.

4-

Use the factory supplied protective tubing.

5-

The field wiring must comply with applicable codes, ordonnances and

regulations.

6-

The furnace fan circuit must be class 2

circuit only

.

LINE VOL

TAGE

LOW VOL

TAGE

AND

FIELD WIRE

COLOR CODE

BK

BLACK

NC

NO CONNECTION

BL

BLUE

O

ORANGE

BN

BROWN

R

RED

G

GREEN

W

WHITE

GY

GREY

Y

YELLOW

DEFROST

TIME

JUMPERS T

ABLE

MODEL

MODEL

DEFROST/VENTILA

TION

TYPES MINUTES

23°F

5°F

-17°F

JU1A

JU1B

JU1C

JU1D

JU1E

JU1F

JU1G

-5°C

-15°C

-27°C

OUT

OUT

IN

IN

OUT

IN

OUT

HR

V

-150

6/32

6/32

6/20

HR

V

-210

OUT

IN

OUT

IN

OUT

IN

OUT

ER

V

-150

6/32

NOTE

NOTE

ER

V

-210

NO

NO

NO

NO

NO

OUT

NO

EXTENDED DEFROST

10/30

10/20

10/15

CHANGE

CHANGE

CHANGE

CHANGE

CHANGE

CHANGE

H

R

V

O

N

LY

Connection

Logic

A

B

C D E F G

2

1

JU 1

. .

. .

. .

. .

. .

. .

. .

FUNCTION

TABLE RELA

Y

MODE K1 K2 K4 K5

Intermittent 0

0 0

0

Exchange Low 1

0

1

1

Exchange High 1

1 1

1

Circulation Low 1

0

1

0

Circulation High 1

1 1

0

Defrost Cycle 1

1 1 0

O

ff 0

0

0

0

0 = Relay coil is de-energized

1 = Relay coil is energized

SPECIAL

DEFROST

CYCLE:

The mode is the same whichever t

h

e

exchange

speed selected by the wall control.

6 min. defrost 34 min. OFF 20 min. exchange low speed

BELOW

-1

5

°C

-

A

change of air exchange speed on the wall

control

(-

5

°F

)

during the special defrost cycle will reset the special

defrost cycle to the beginning (6 min. defrost).

-

The override circuit will remain active during the

special defrost cycle.

An override call will be answered.

-

If the outside temperature revert above -15°C (5°F),

it is only during the last part of the cycle (20 min.

exchange) that the controller will stop the special

defrost cycle.

NOTE

WARNING

010

!

Risk of electrical shocks. Before performing any maintenance or servicing, always disconnect the
unit from its power source.