Recording, Recording methods, Recording types – MITSUBISHI ELECTRIC DX-TL5716U User Manual

Page 52

Advertising
background image

48

Recording methods

To record images, you can use any of three methods as
follows.

Manual recording (

page 65)

When you press the REC/STOP button on the front panel of
the recorder, recording starts. The recording picture quality
and FPS of Recording A are applied.

Press the REC/STOP button
to start or stop recording.

Timer recording (

pages 66 to 69)

Recording starts or stops automatically according to the
preprogrammed schedule at the recording picture quality
and FPS that are preset to Recording A to Recording D.

Sun
Mon
Tue
Wed
Thu
Fri
Sat
Hol

00 : 00

06 : 00

12 : 00

18 : 00

24 : 00

REC A

REC B

REC C

REC D

Archive

Recording starts
and stops
according to the
preprogrammed
schedule.

Recording start/stop triggered by external contact signal

You can start or stop recording using the EVENT terminals
of the I/O terminals on the rear panel of the recorder. (

page 108)

The settings of Recording A are used in this recording
method.

This function doesn't work during timer recording.

Recording types

Normal recording

Recording is performed at the recording picture quality and
FPS you preset for normal recording.

Alarm recording

Upon receipt of a trigger for starting alarm recording, the
recorder starts recording at the recording picture quality and
FPS you preset for alarm recording.

You can configure advanced recording settings by
making settings for normal recording and alarm recording
separately. For example, you can change the FPS rate
of the camera used for alarm recording while keeping the
normal recording settings.

Pre-alarm recording

Pre-alarm recording is a function to start recording
maximum 30 minutes before the start of alarm recording.

Emergency recording

When the EMERGENCY terminal receives a signal, the
recorder starts recording images from all the selected
cameras with the highest picture quality based on the FPS
rate you preset for emergency recording.

Pre-emergency recording

Pre-emergency recording is a function to start recording
maximum 30 minutes before the start of emergency
recording.

Alarm recording • Pre-alarm recording

Emergency recording • Pre-emergency recording

Time

Event occurs.

Images before the trigger input
are recorded to the HDD.

Camera input

Recording

Recording

Pre-alarm recording

Alarm recording

Time

Event occurs.

Images before the trigger input
are recorded to the HDD.

Camera input

Pre-emergency recording Emergency recording

Input of a trigger for

starting alarm

recording

Signal input to the

EMERGENCY terminal

on the rear panel

Recording

Advertising