Sanyo PLC-WXE46 User Manual

Page 27

Advertising
background image

PLC-WXE46/WXL46

Expand Serial Command Functional Specifications

27/65

8.7.3

CF_KEYSTONE Command

Command “CF_KEYSTONE_%1”[CR]

%1

“UP” ------------- Correct Keystone distortion to reduce upper part of image
“FUP” ----------- Correct Keystone distortion to reduce upper part by 2steps
“DN” ------------- Correct Keystone distortion to reduce lower part of image
“FDN” ----------- Correct Keystone distortion to reduce lower part by 2steps
“RST” ------------ Set Keystone OFF

Details

Change Keystone distortion correction
This command is available in normal Power ON status.

Response

Acceptable

“000”[CR]

Unacceptable

“Error Code”[CR]
“201”[CR] ----When reaching the Keystone correction limit or

reaching 1 step to correction limit and “FDN”/”FUP”
is received.
(The command is not executed)

8.7.4

CF_KYSTNMODE Command

Command “CF_KYSTNMODE_%1”[CR]

%1

“STR” --------- Set Keystone store mode to Store
“RST” --------- Set Keystone store mode to Reset

Details

Set Keystone store mode
This command is available in normal Power ON status.

Response

Acceptable

“000”[CR]

Unacceptable “Error Code”[CR]

8.7.5

CF_VSCALE Command

Command “CF_VSCALE_%1”[CR]

%1

“032” --------- +32
“031” --------- +31

“002” --------- +2
“001” --------- +1
“000” --------- +0
“-01” ---------- -1
“-02” ---------- -2

“-31” ---------- -31
“-32” ---------- -32
“UP” ---------- Vertical Scale setting value + 1
“DN” ---------- Vertical Scale setting value - 1

Details

Set Vertical Scale
This command is available in normal Power ON status.
Note1) When Screen setting is not Custom, projector returns 101[CR] and the
command does not excute.
Note2) When there is no Input, projector returns 101 and the command does not
excute.

Response

Acceptable

“000”[CR]

Unacceptable “Error Code”[CR]

Advertising