Sanyo PLC-WXE46 User Manual
Page 60

PLC-WXE46/WXL46
Expand Serial Command Functional Specifications
60/65
9.11.20 CR_FANCONTROL Command
Command “CR_FANCONTROL”[CR]
Details
Get selected Fan control setting status
Response
Acceptable
“000_%a”[CR]
%a
“OFF” ----------------------- Fan control is OFF
“ON1” ----------------------- Fan control is ON1
“ON2” ----------------------- Fan control is ON2
“ON3” ----------------------- Fan control is ON3
Unacceptable “Error Code”[CR]
9.11.21 CR_FILH Command
Command “CR_FILH”[CR]
Details
Get Filter used time
Response
Acceptable
“000_%1”[CR]
%1
“00000”~”99999” ------------------- 0 hour to 99999 hours
Unacceptable “Error Code”[CR]
9.11.22 CR_FILREPL Command
Command “CR_FILREPL”[CR]
Details
Get the information of Filter replacement time
Response
Acceptable
“000_%1”[CR]
%1
“1Y” ------------------- Over filter replacement time
“1N” ------------------ Within filter replacement time
Unacceptable “Error Code”[CR]
9.11.23 CR_FILTIMER Command
Command “CR_FILTIMER” [CR]
Details
Get setting time which filter warning OSD is displayed
Response
Acceptable
“000_%1”[CR]
%1
“100” ----------------- 100 hours
“200” ----------------- 200 hours
“300” ----------------- 300 hours
“OFF” ---------------- No OSD display
Unacceptable “Error Code”[CR]
9.11.24 CR_CCAPTIONDISP Command
Command “CR_CCAPTIONDISP”[CR]
Details
Get selected channel of Closed caption
Response
Acceptable
“000_%a”[CR]
a
“OFF” --------- Off
“CC1” --------- CC1 is selected
“CC2” --------- CC2 is selected
“CC3”--------- CC3 is selected
“CC4” --------- CC4 is selected
Unacceptable “Error Code”[CR]