Sanyo PLC-WXE46 User Manual

Page 60

Advertising
background image

PLC-WXE46/WXL46

Expand Serial Command Functional Specifications

60/65

9.11.20 CR_FANCONTROL Command

Command “CR_FANCONTROL”[CR]

Details

Get selected Fan control setting status

Response

Acceptable

“000_%a”[CR]

%a

“OFF” ----------------------- Fan control is OFF
“ON1” ----------------------- Fan control is ON1
“ON2” ----------------------- Fan control is ON2
“ON3” ----------------------- Fan control is ON3

Unacceptable “Error Code”[CR]

9.11.21 CR_FILH Command

Command “CR_FILH”[CR]

Details

Get Filter used time

Response

Acceptable

“000_%1”[CR]

%1

“00000”~”99999” ------------------- 0 hour to 99999 hours

Unacceptable “Error Code”[CR]

9.11.22 CR_FILREPL Command

Command “CR_FILREPL”[CR]

Details

Get the information of Filter replacement time

Response

Acceptable

“000_%1”[CR]

%1

“1Y” ------------------- Over filter replacement time
“1N” ------------------ Within filter replacement time

Unacceptable “Error Code”[CR]

9.11.23 CR_FILTIMER Command

Command “CR_FILTIMER” [CR]

Details

Get setting time which filter warning OSD is displayed

Response

Acceptable

“000_%1”[CR]

%1

“100” ----------------- 100 hours
“200” ----------------- 200 hours
“300” ----------------- 300 hours
“OFF” ---------------- No OSD display

Unacceptable “Error Code”[CR]

9.11.24 CR_CCAPTIONDISP Command

Command “CR_CCAPTIONDISP”[CR]

Details

Get selected channel of Closed caption

Response

Acceptable

“000_%a”[CR]

a

“OFF” --------- Off
“CC1” --------- CC1 is selected
“CC2” --------- CC2 is selected
“CC3”--------- CC3 is selected
“CC4” --------- CC4 is selected

Unacceptable “Error Code”[CR]

Advertising