Figure 4-15. trig1 input signal timing, Figure 4-16. trig1 output signal timing, Trig2 signal – National Instruments AT E Series User Manual

Page 81: Trig2 signal -34

Advertising
background image

Chapter 4

Connecting Signals

AT E Series User Manual

4-34

ni.com

Figures 4-15 and 4-16 show the input and output timing requirements for
the TRIG1 signal.

Figure 4-15. TRIG1 Input Signal Timing

Figure 4-16. TRIG1 Output Signal Timing

The device also uses the TRIG1 signal to initiate pretriggered DAQ
operations. In most pretriggered applications, the TRIG1 signal is
generated by a software trigger. Refer to the TRIG2 signal description for
a complete description of the use of TRIG1 and TRIG2 in a pretriggered
DAQ operation.

TRIG2 Signal

Any PFI pin can externally input the TRIG2 signal, which is available as
an output on the PFI1/TRIG2 pin.

Refer to Figure 4-13 for the relationship of TRIG2 to the DAQ sequence.

As an input, the TRIG2 signal is configured in the edge-detection mode.
You can select any PFI pin as the source for TRIG2 and configure the
polarity selection for either rising or falling edge. The selected edge of the
TRIG2 signal initiates the posttriggered phase of a pretriggered acquisition
sequence. In pretriggered mode, the TRIG1 signal initiates the data
acquisition. The scan counter indicates the minimum number of scans

Rising-Edge

Polarity

Falling-Edge

Polarity

t

w

= 10 ns minimum

t

w

t

w

= 50 to 100 ns